The Hidden Power Drain in TOPCon Modules: Your Guide to UV-Induced Degradation (UVID)

  • Home
  • Blog
  • The Hidden Power Drain in TOPCon Modules: Your Guide to UV-Induced Degradation (UVID)

You’ve invested in the future—high-efficiency N-type TOPCon solar modules. They promise superior performance and a lower levelized cost of energy. But what if the very sunlight they’re designed to capture is causing an unexpected, initial drop in power that standard tests don’t see coming?

This isn’t a hypothetical problem. It’s a phenomenon known as UV-Induced Degradation (UVID), and it’s a critical topic for anyone involved in solar module manufacturing and deployment. This subtle but significant power loss occurs early in a module’s life, and understanding it is essential for ensuring your product’s performance matches its promise.

What Is UV-Induced Degradation (UVID), and Why Does It Affect TOPCon?

Degradation is a natural part of any solar module’s lifecycle. We’ve known about Light-Induced Degradation (LID) for years, but UVID is different. It’s a degradation mechanism specifically triggered by ultraviolet (UV) light, and it has a particular affinity for modern, high-efficiency N-type TOPCon (Tunnel Oxide Passivated Contact) cells.

The „magic“ in a TOPCon cell lies in its sophisticated passivating contact structure—a microscopic layer that is highly effective at preventing energy loss. However, this same structure has shown a sensitivity to UV radiation. When exposed to UV light, especially in combination with certain module materials, this sensitive layer can be altered, causing an initial power drop that can reach up to 2%.

Think of it like this: your brand-new module performs perfectly in the factory flasher. But after a few weeks in the field, its output is noticeably lower. The culprit isn’t poor manufacturing; it’s a physical reaction that was never accounted for.

The Challenge: A Two-Part Problem

What makes UVID in TOPCon so tricky is its two-stage behavior:

  1. Initial Degradation: The power loss is triggered by UV exposure. This happens relatively quickly once the module is installed.
  2. Partial Recovery (Stabilization): Here’s the interesting part. After the initial drop, the module can regain some of its lost power when exposed to regular sunlight in a process called light soaking. However, this recovery is often incomplete, and its behavior is unpredictable without specific testing.

This leaves manufacturers with a critical question: What power rating should you put on the datasheet? The initial „fresh“ state? The fully degraded state? Or the final, stabilized state? Guaranteeing performance without this data is a significant financial and reputational risk.

Why Standard Certification Tests Are Missing the Mark

You might assume that standard IEC certification protocols would catch this. The reality is, they weren’t designed for it. Traditional tests for UV stability (like IEC 61215) focus on the long-term integrity of module materials like backsheets and encapsulants, not on the nuanced cell-level degradation that defines UVID in TOPCon.

The unique „degrade-then-recover“ signature of UVID requires a more specialized approach. Simply blasting a module with UV light and measuring the result only tells half the story. To truly characterize its real-world performance, you need to see the whole picture: the initial drop and the subsequent stabilization.

This is where a dedicated testing protocol becomes essential, moving beyond simple certification to provide true performance validation. These insights are crucial for anyone involved in solar module prototyping and aiming for a bankable, reliable product.

Characterizing UVID: A Two-Step Protocol for Predictable Performance

At PVTestLab, we’ve developed a specialized protocol designed to quantify the UVID effect in TOPCon modules. It’s a systematic approach that simulates the module’s early life in the field, providing clear, actionable data on its degradation and stabilization behavior.

Stage 1: Controlled UV Exposure

The process begins by isolating the UV trigger. The module is placed in a climate-controlled chamber and subjected to a precise dose of UV radiation—typically 15 kWh/m². This is enough to fully initiate the degradation mechanism.

During this phase, we also consider the role of the surrounding materials. The type of encapsulant used, most notably Polyolefin Elastomer (POE), can influence the severity of the UVID effect. This is why holistic material compatibility testing is a crucial part of developing a robust module design. We meticulously measure the module’s power (Pmax) before and after this stage to quantify the maximum potential power loss.

Stage 2: Light Soaking and Stabilization

Once the initial degradation is complete, the module is moved to a light soaker. Here, it’s exposed to simulated sunlight at a standard intensity (1000 W/m²) and controlled temperature. This mimics the conditions it would experience in the field, allowing the natural recovery process to begin.

We take periodic measurements during this phase to plot the recovery curve. This reveals two critical pieces of information:

  • How much power is recovered?
  • How long does it take to stabilize?

„The goal isn’t just to measure degradation; it’s to understand the stabilization dynamics,“ notes Patrick Thoma, a PV Process Specialist at PVTestLab. „This gives manufacturers the confidence to define accurate datasheet values and guarantee long-term performance for their customers.“

By understanding this curve, manufacturers can confidently label their modules based on their stabilized power output, ensuring that customer expectations are met and financial models for solar projects remain accurate. The data from these tests can then be used to refine bills of materials and production steps, providing key input for process optimization services.

Frequently Asked Questions (FAQ)

Q1: What is TOPCon technology?
A1: TOPCon (Tunnel Oxide Passivated Contact) is an advanced solar cell technology used in modern N-type cells. It adds an ultra-thin layer of tunnel oxide and a layer of polysilicon to the cell’s rear surface, which significantly reduces energy losses and boosts overall efficiency compared to older technologies like PERC.

Q2: Is UVID the same as LID (Light Induced Degradation)?
A2: No, they are different phenomena. LID is a well-known issue primarily affecting P-type cells and is caused by Boron-Oxygen complexes that form under sunlight. UVID is a distinct mechanism triggered by UV radiation that specifically impacts the passivating contact structure of N-type cells like TOPCon.

Q3: Does UVID affect all solar panels?
A3: UVID, in this specific context, is a known concern for N-type TOPCon modules. While other technologies can be affected by UV radiation over their lifetime (usually material yellowing or delamination), this particular „degrade-and-recover“ power loss behavior is characteristic of the TOPCon cell architecture.

Q4: Why is POE encapsulant often mentioned with UVID?
A4: Encapsulants like POE are used to seal and protect the solar cells within the module. Research suggests that byproducts or additives within some encapsulants may interact with the TOPCon cell surface under UV exposure, potentially contributing to or accelerating the UVID effect. Testing different encapsulants is key to mitigating this.

Q5: How long does a UVID test take?
A5: A full UVID characterization test, including the initial UV exposure phase and the subsequent light soaking until stabilization, typically takes several days to complete. The exact duration depends on how quickly the module reaches a stable power output during the light soaking phase.

From Uncertainty to Confidence

The rise of TOPCon technology represents a major leap forward for the solar industry. But with any new innovation comes new challenges. UV-Induced Degradation isn’t a reason to doubt the technology, but it is a compelling reason to embrace more sophisticated testing.

By moving beyond standard certification and adopting specialized protocols that characterize UVID, module manufacturers can eliminate performance uncertainty, deliver on their promises, and build a more reliable and bankable product. It’s about replacing assumptions with data and turning a hidden risk into a competitive advantage.

Ready to see how applied research and real-world process validation can de-risk your next-generation module design? Explore how PVTestLab bridges the gap between the laboratory and full-scale production.

You may be interested in